500-9041 v4.1
Welcome Report
Control
Admin Sys Config Tech-Ref
83
- Door
(bottom of form)
:
This is where
you select a door to view its status or
issue commands. This shows a
reference number assigned by the
system, plus the name/description of
the door as defined under
'Configuration'.
If some Door numbers are missing:
Elevator and door numbering is shared (1 -
32), but the elevators will not be listed here.
-Door Command:
Shows the status of
the selected door, and provides
selections for unlocking/relocking it (if
you have the authority).
If cards are presently 'locked-out', you'll need to
reinstate card-access before unlocking the door. (Set
the "Reader State" as "Normal".)
Tip:
"Momentary" pertains to the defined "Unlock
Duration" (such as when a person uses their access
card), and "Pending" means the command will be held
until after one valid user gains entry at the door.
- Door Status, Door Alarm
, and
"Wandering
Patient":
The present status of the door, and
whether or not this is considered to be an 'alarm'
(i.e., 'not OK'), plus whether or not the
"wandering Patient" feature is in effect for this
door.
-Tamper:
Whether or not tampering has been
detected for the RTE (REX) circuit, the main
reader, or the auxiliary reader.
- Reader 1 / Reader 2 In Area X:
Status topics
for the selected reader and its associated area,
plus selections for controlling each reader (if
you have the authority). Selections include
lockout or reinstate card access, and/or change
various operating characteristics.
Locking-out cards automatically causes the door to
lock.
For details on the various reader modes, card modes,
and class map settings, refer to "Doors, Readers, and
Related Settings".