215
Pick Lists
(bottom of the form)
-Panel Group
&
Panel
references (optional;
bottom of the form)
:
This is where you
select a specific panel-group and panel in a
multi-panel system where the 'tree' is
not
set to show items on a panel-by-panel
basis. For more information on this feature,
refer to "Other Desktop Choices".
- Custom Point Type
(bottom of form)
:
This is where you select a custom
point-type to view or edit. This area
shows a reference number assigned
by the system, and the description,
once defined;
Note:
Similar to physical items in a
system, each custom point-type pertains to an
individual panel.
On This Form
(Standard )
- Name:
A suitable name indicating the operation
or usage for this custom point type;
- Preprocess:
The duration that the point must
REMAIN triggered before an alarm will be
audited, or the point type / operation;
Extended: This pertains to garage door sensors, and
other applications where a longer delay time is
desired. With this setting, the area "Extended" delay
will apply, and the area can be armed while the input
is 'tripped'.
Guard Tour: This pertains to guard-tour checkpoints
(stations).
For this application:
+
The 'class' should be set as "supervisory";
+
The 'level' will typically be set as "24hr";
+
Any "Transmit" selections will be ignored (guard-tour
point activity is referenced locally during the
monitoring of a guard-tour).
Work Late: This pertains to a button that can be
pressed to set/delay the scheduled closing time for the
area associated with the input-point. To set the time
extension for a 'work late' point, refer to the "Work
Late Input Point" setting under "Areas and Related
Settings".
Door: The 'Door' selection is normally used with doors
that are monitored, but not electronically controlled for
personnel access. For access-controlled doors, a
dedicated 'Door Contact' input is provided on the door-
control module (which is set up through the
Door
screen). As well, door inputs cannot be set for a 24-hr
monitoring, and cannot be bypassed (regardless of
whether "bypassable" is selected or not).
Keyswitch Arming/Disarming: With 'pre-process' set
to "Keyswitch...", the "Level" setting provides
selections for "Arm" and "Disarm". The chime
operation changes as well: If "Chime (
√
)",
and
the
area is set for "Stay on Fail to Exit", the area will be
armed to 'Stay' if no users exit after turning the switch
(not-Ok to Ok
). Conversely, if the chime is not
selected, the "Stay on Fail to exit" setting will be
ignored (the area will fully arm to 'On').
Note:
With an
arming keyswitch, disarming is typically done through
an LCD keypad.
- Level:
The arming levels of the area assigned to
the point for which the point will be fully
monitored by the system.
Exception: For keyswitch operation, see the previous
"Keyswitch" note.
- Class:
The basic classification for the point /
sensor (this is referenced in messages
transmitted to the monitoring station);
-------------------------
- Bypassable:
Whether or not the point can be
bypassed (by a user with 'bypass' authority)
should the need arise (e.g., to allow arming an
area with a broken window, faulty sensor, etc.).
-Chime:
Whether or not three short beeps will be
signalled at keypads in the area assigned to this
point whenever the point is triggered (this can
be ‘toggled’ off at a keypad by pressing ƒ5);
Exception: For keyswitch operation, see the previous
"Keyswitch" note.
- Pre-Alarm Warning:
For associated input-
points, alarm transmission (to the central
station) will be delayed as per the "Pre-Alarm
Delay" setting (for the specific 'area'). During
the delay, keypad sonalert(s) will be sounded,
giving an authorized user time to "Silence" the
alarm at a keypad. (Selecting "Verify User" will
Configuration
Custom Point Types