500-9041 v4.1
Welcome Report Control Admin Sys Config
Tech-Ref
271
For each Main Panel (as per software
licensing and 'Feature-Set')
† Supported 'feature-set' depends on your software
licensing (as manged through the license-manager
software). Feature-sets higher than 4 are supported
only with the "Enterprise" version of MONITOR AFx
Director.
* Local user admin. (via keypad) is supported in all
systems, while local system configuration is supported
only in single panel systems set to "
Feature Set
" 1, 2,
3, or 4.
Exception:
Keypad programming is
supported in all systems for any 'application' modules
that require this due to custom settings stored only at
the module itself (HSC/printer module, RF/wireless
module, and Smart PODs).
For details on setting the 'memory model', refer to
"Account-Wide Panel Settings...".
Common Per-Panel Capacities
(not based on 'Feature-Set')
Expansion / Application Modules:
24
system LCD keypads and/or other modules, or
60
suite-security keypads (see exceptions).
Exceptions: Suite-security keypads can be mixed with
other modules if desired (the capacity for suite-security
keypads is reduced by
5
for each system LCD
keypad,
and each other expansion / application module added.
(For example, with 2 system keypads, 3 door
controllers, and one point expansion module, a full-
capacity "Enterprise" system could still support 30
suite-security keypads).
Converted TDC/PDC Door Controllers: Up to 10 per
panel (combined total).
Areas:
16 monitored 'areas' per panel;
Doors:
The "Enterprise" version of the
software supports up to
32
doors
per panel
.
The "Prime" version supports a
single panel
with
16
doors
.
Elevators:
The "Enterprise" version of the
software supports up to
32
elevator (lift) cabs.
Exception: This is shared with the door capacity (max.
32
combined total).
Floors:
The "Enterprise" version of the
software supports 124 unique access-
controlled floors.
(These can be in a single building,
or the combined total across multiple buildings.)
Monitored Sensors (Input Points):
128 per
panel (8 of which are physically on the main
panel itself).
Programmable Outputs:
124 per panel (plus
4 internal outputs that can be used with the
paging feature).
Feature
Set
Required
RAM
Expansion
Authority
Levels
History
Events
(Logs)
Users User
Names at
Keypads
User
LogOn
Number of
Panels Allowed
in System
1 *
None 30 1024 20 Yes Pin Only 1 Only
2 *
None 30 1024 100 Yes 2d ID + Pin 1 Only
3 *
None 30 1024 300 Yes 3d ID + Pin 1 Only
4 *
None 100 2048 1000 Yes 3d ID + Pin 1 Only
5
†
None 100 2048 1000 Yes 3d ID + Pin Multiple
6
†
None 100 2048 2000 Yes 4d ID + Pin Multiple
7
†
None 100 1024 4000 No 4d ID + Pin Multiple
8
†
512K Bytes 500 8192 10000 Yes 4d ID + Pin Multiple
9
†
512K Bytes 500 8192 10000 No 4d ID + Pin Multiple
10 † 1M Bytes 500 8192 20000 Yes 5d ID + Pin Multiple
11 † 1M Bytes 1000 16384 20000 No 5d ID + Pin Multiple
12 † 1M Bytes 1000 16384 20000 Yes 5d ID + Pin Multiple
13 † 2M Bytes 1000 65536 64000 No 5d ID + Pin Multiple
14 † 2M Bytes 1000 32768 64000 Yes 5d ID + Pin Multiple