500-9041 v4.1
Welcome Report Control Admin Sys Config
Tech-Ref
247
Panel & Software Revisions:
Monitor
AFx Director software
V3.2
and higher
can connect with panels
V2.0
and higher.
Associated panels must be the same rev.
level, and the Director software must
typically be upgraded to the same level or
higher. Exception: V3.3 panels OK with
V3.20 software for this type of connection
(i.e., non-IP).
Single-Panel, Close to the
PC
(RS-232 / Connection Kit)
The MONITOR AFx Director
software includes a connection kit
that simplifies the PC-to-alarm-
panel connection for a single panel
(direct, RS-232 connection). Refer
to the illustration to complete the
panel connection.
Multi-Panel, and/or far
From the PC (RS-485
Adapter)
For longer distances, and/or multiple panels
per connection, the MONITOR AFx RS485
converter is required. Refer to the illustration
for connection details.
Tip:
An RS485 connection supports distances of at
least 300 m (1000 feet) in total length.
PC-to-Panel—Direct Connection
22 or 24 AWG,
4 conductors
Max: 16 M / 50 ft.
Main
System Panel
1432
5
1432
TB14 TB15
red
green
black
Cable Shield:
(if present) connect
to the panel
waterpipe ground.
GND/GND
RX
TX
If 'twisted-pair' cable:
Use one wire from each pair for
Tx & Rx, and connect the other
wire from each pair to ground.
Do NOT use
reader cable!!
TX
120-8503
312
RX
GND
black
green
red
DB9 RS232
Adapter Plug
To PC
comms port
Cable Shield:
(if present) do not
terminate at Adapter end.
NOTE:
Adapter Plug TX connects
to RX at motherboard. Adapter Plug
RX connects to TX at motherboard.
Panel
Main PCB
1432
5
1432
CTS/RTS
RTS/CTS
DSR/DTR
DTR/DSR
RI/RI
CD/CD
TB14 TB15
green
black
132
TB16
0V
B
A
white
RS485
RX/RX
TX/TX
GND/GND
A
B
GND
+12V
GND
green
black
white
RS485
converter
100-2185
DB9
(insert into free
serial port on the
specific PC)
RS485 Communication Cable P/N
120-3401
Cable shield (do not
ground at the PC
Note:
The "A" and
"B" connections here
are reversed relative
to the panel(s).
To additional panels (up to 30)
0V
B
A
(24 AWG, 4 wires, shielded)
Cable Shield: Connect
to the chassis/earth
ground at one panel
only
(e.g., 1st or last)