21-3601E rev1.3 xL Simplified Installation Guide 23
Underwriters’ Laboratories Inc.
(U.L.) Listed systems: Notes
and Requirements
Installation Notes
• For all U.L. Listed applications the auxiliary power
available is 1.0A.
• A U.L. Listed power transformer (16.5 V. 40 VA.
class 2) must be used on this system
(Amseco model XP-1640 or equivalent).
• For U.L. Listed residential applications a listed
siren (Ademco model 747 or equivalent) must be
used.
• For UL Listed residential applications a listed siren
supervision module (FBII model BSSM or
equivalent) must be used.
• For U.L. Listed non-residential applications a listed
bell and bell housing (Ademco model AB12M,
Rothenbuhler model 5110 or equivalent listed)
must be used.
• For U.L. Listed non-residential applications the
control panel must be of the type in an attack
resistant enclosure.
• Ground start modules are not permissible for
residential fire alarm systems in accordance with
NFPA 72.
• The bell / siren must be located where it can be
heard by the person or persons responsible for
maintaining the security system during the daily
arming cycle.
• Control units intended to be located outside of the
complete vault, a complete safe, or an extent
number 1 stockroom, shall be protected with a
attack sensor (Sentrol p/n 573-1006 or
equivalent).
• “*” keypad button designates an alert signal. Do
not program as a fire or burglary signal.
• Audible alarm designations:
Fire – 3-pulse temporal,
Burglary – Steady,
Alert – Beeping.
Programming Notes
• For central station and police connected systems
the U.L. dialing option (including closing ring back
feature) must be turned ON – (refer to System
Simplified Configurations: “Audible Ringback” and
select Yes).
• Initiating circuits for residential Grade A burglary or
fire must be supervised with a standard end of line
2.2 KΩ resistor PN 705-4250. Furthermore, all fire
initiating circuits must be programmed for no delay
– (refer to Points Simplified Configurations: Fire -
immediate).
• For commercial installations, the control box
actuator must be programmed for full reporting
and siren activation; Equipment Simplified
Configurations: E01, all fields must be turned ON.
This will allow the control unit that contains the
DACT (Digital Alarm Communicator Transmitter)
to be fully protected 24 hours a day.
• The control panel battery must be supervised for
failures. Activate the battery monitoring in
Equipment Simplified Configurations: E02 and
enable all fields for the keypad tone and
transmissions to the monitoring station.
• Remote programming must be disabled. U.L. does
not list systems with active upload / download
capabilities. For listed installations in the
“Powering on the System for the First Time” –
“Remote Connection” section of this manual, do
not program a unique system I.D. number and do
not program a configuration telephone number.
The system will no longer be up / downloadable.
• The minimum siren time required for Listed
systems is as follows:
Household fire and burglary: 4min.
Bank safe and vault: 5min
Mercantile: 15min
Make these selections in System Simplified
Configurations: “System Time”.
• System shall be programmed to give priority as
follows:
1. Fire alarm and industrial supervision where a
risk of injury to persons, or damage or
destruction of property may be involved.
2. Panic alarm.
3. Burglar alarm.
4. Fire –alarm supervisory.
5. Burglar-alarm supervisory.
Entry & Exit Delays
The maximum entry delay time for
commercial
systems is 45 seconds.
The maximum exit delay time for commercial
systems is 60 seconds.
The maximum entry delay time for residential
systems is 45 seconds.
The maximum exit delay time for residential
systems is 60 seconds.
Testing
Weekly testing of the bell/siren is required. Please
instruct your customer to use the TEST feature.
For an LCD keypad enter a valid code, select the
TEST menu and then select the SYSTEM option.
Yearly testing of communication formats is required.
This is done by enabling the communications test a
minimum of one year or a shorter duration. Set the
“Comms Test Delay” in Simplified Configurations for
the desired time.
Partitioned Systems
For partitioned systems the protected area must be
under the responsibility of one ownership and
management. This may be a group of buildings
attached or unattached and may even have different