21-3601E rev1.3 xL Simplified Installation Guide 15
Arm Disarm Map
(Arm/Disarm other
areas)
Press the button below “ÈEdit “ to make changes. Scroll through the areas at the top of the
screen using the left and right keypad arrows. When an area appears that needs to be
armed /disarmed from this keypad, press the keypad button below ÈYes or ÈNo to assign
the other area(s) to this keypad. A check mark
9will appear beside the Yes or No selection.
Default:
9(Yes) for Area 1
Exit Delay Map
(what areas will
there be an exit
delay in)
Press the button below “ÈEdit “ to make changes. Scroll through the areas at the top of the
screen using the left and right keypad arrows. When an area appears that needs to also
have an exit delay when the area this keypad is assigned to is armed, press the keypad
button below ÈYes or ÈNo to assign the other area(s) to this keypad. A check mark
9will
appear beside the Yes or No selection. Default:
9(Yes) for Area 1
Single Badge Mode
System response when
momentarily touching an access
card etc. to e.g. an LCD G-Prox
keypad.
Selections:
Tgl (toggle)OFF-ON, TglSTAY-
ON, Ext Exit Dly (external exit
delay), Work Late, None, Auto
logon, Arm ON, Arm ST (Stay)
DisarmSTAY, Disarm OFF.
Hold Badge Mode
Selections:
None, Auto logon, Arm
ON, Arm ST (Stay),
DisarmSTAY, Disarm
OFF, Tgl (toggle) OFF
STAY, Tgl OFF-ON,
TglSTAY-ON, ExtExitDly
(external exit delay), Work
Late.
Default: Auto log on
(UK ACPO = Disarm OFF)
Default: Tgl OFF-ON
(UK ACPO = “Arm ON”)
Points
Point Types: EE(entry/exit)Door, EE Route, Perimeter, Motion, Fap Motion, Day Warning, Burglary, Fire Class A, Fire
15s (second), Fire 0s (immediate), Hold-up, Aux Alert (auxiliary alert/emergency), Supervisory, Local 24h (hour), Lcl
StayOn (Local Stay-On), Lcl Stay20n, Local On Only, undefined.
FAP: (False Alarm Preventor) If a FAP input is not OK longer than 10 seconds, an alarm condition occurs. If a FAP input is triggered and
immediately resets, a 20 minute timer begins. If the same device is tripped or a different FAP device trips in the same 20 minutes, an alarm occurs.
Circuit Types: NC (normally closed), NC SERIES2K (normally closed with 2.2K End of Line resistor), NO PARALL2K
(normally open with 2.2K End of Line resistor), DUAL 2K2 EO (Form “C” Dual 2.2K End of Line resistor )
Circuit Types UK:
NO, 2K-ALM 1K-0, Type2 2K2E0, Type2 8K2E0.