22 xL Simplified Installation Guide
21-3601E rev1.3
Diagnostics
The system is capable of self trouble shooting itself
which can be helpful to the technician in determining
causes of various faults.
• With the control box tamper activated, log on to the
system as a service user. E.g. Default ID: “000”,
service user PIN: “2482” or “7378” if the panel has
communicated with the Director Software.
NOTE: If the system Feature Set is 5 or greater,
keypad programming can not be done.
Programming can only be done with the Director
Software. See the Advanced Installation Guide
500-3652 for further information.
LCD Keypad Screen
Menu Options
◄ Status ►
↓Ok
• Using the left and right
arrow screen scrolling
keys on the keypad
scroll the menus until Status is displayed. Press
Ok.
Status Options
◄ System ►
↓Ok
• Using the left and right
arrow keys on the
keypad, the Status
options can be scrolled to display several system
conditions. When the desired one to view is
displayed, press Ok.
Keypad Status Diagnostic Selections
System: displays general system conditions, tampers, faults etc.
Points: displays area’s set armed levels, input point conditions.
iSNAPP: displays conditions of modules on the module bus and the bus itself.
Modem: displays the condition of a modem connected to the system.
Licns: the available features enabled through the system License Agreement.
Bell 103: the condition of a communication land line connected to the system.
PnlD/jointfilesconvert/416907/bg (Panel Debug): Stack (firmware related), Timing, Inputs, P. Supply (power supply), 8 OP STU (8 output
subscriber terminal unit), BCapl Err (output error), DOC Info, Voltages, Watch Dog.
SIP Com: condition of Security IP Communications.
Outputs: output conditions.