Verex Monitor ISM Guida di Installazione Pagina 26

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 34
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 25
20 xL Simplified Installation Guide
21-3601E rev1.3
B001 – B128 Protection Points
Select Point #
Normal, Not Normal, Day Not Normal, Nite (Night)
Not Normal, Alarm, Bypassed, Dly prepro (Delay
Preprocess), Tamper, Point Delay, Pos (Positive)
Confirm.
Toggle, Normal, Time
Delay or Inverted
B001 – B128 Outputs
Select Output #
Real OP (output) On, Equation is True, Manual
Command.
Toggle, Normal, Time
Delay or Inverted
B001 – B128 Modules
Select Module #
On Line, Tamper, Comms Trbl, (Communications
Trouble), Battery Trouble, User Loged On.
Toggle, Normal, Time
Delay or Inverted
B001 – B128 Equipment Points
Select Point #
System Tmpr (Tamper), Low/No Battery, AC Mains
Failure, No Phone Line, Report Delay, Time Lost,
Time Change, Progr (Program) Edit , Progr
(Program) Error, Fuse Fail, Pod (Module) Trouble,
Pod Bat (Module Battery) Low, Pod Prg (Module
Program) Edit, Pod Prg Err (Module Program
Error), Oup Troubl (Output Trouble), HSC Troubl.
Toggle, Normal, Time
Delay or Inverted
UK Output Default
Select Output Select Group
(Program
Section)
Select Area,
Point, etc.
Select Condition Select
Operation
B001 Relay 1
motherboard
System 000.66 ACPO Siren Inverted
B002 Relay 2
motherboard
System 000.67 Confirmed Alarm (ACPO strobe) Inverted
B003 WW STU Areas Area 1 001.33 When area Entry / Exit delay is in
progress – provides a steady output
(STAY & ON).
Normal
B004 WW STU System 000.60 Personal ACPO Attack Normal
B005 WW STU System 000.61 ACPO Unconfirmed Alarm Inverted
B006 WW STU System 000.62 ACPO Area Set / Unset Inverted
B007 WW STU System 000.64 ACPO Bypass in Effect Inverted
B008 WW STU System 000.54 Local AC (mains) failure. Inverted
B009 WW STU System 000.65 ACPO Confirmed Alarm Inverted
B010 WW STU Areas Area 1 001.32 Area is in ‘Walk’ or ‘Hold-up’ test. Inverted
B011 – B128 Undefined
WW STU = World Wide modem with outputs
Circuits
Input Circuit Types and Defaults (Also programmable in Advanced Programming using the Advanced Programming
Guide, Section S007:01)
North America Circuit Types and Defaults
Select Circuit Circuit Name Type Resistor Configurations
(TYPE1 NC, TYPE2 NO, TYPE3 NC Single
Series ,TYPE4 NC Single Parallel , TYPE5 NO
Single Series , TYPE6 NO Single Parallel
,TYPE7 NC Dual Type 1 , TYPE8 NC Dual
Type 2 , TYPE9 NO Dual Type 1 , TYPE10 NO
Dual Type 2)
Custom Resistor Values
C01 NC 1 Normally Closed No resistor
C02 NC SERIES2K2 3 NC Single (resistor) Series R1 (ohms)
00000
C03 NO PARALL2K2 6 NO (normally open) Single (resistor)
Parallel
R1 (ohms)
00000
C04 DUAL 2K2 EOL 8 NC Dual Type 2 R1 (ohms) R2 (ohms)
00000 00000
Vedere la pagina 25
1 2 ... 21 22 23 24 25 26 27 28 29 30 31 32 33 34

Commenti su questo manuale

Nessun commento