21-3601E rev1.3 xL Simplified Installation Guide 19
Outputs (North America version)
Select Output?
B001
S000.07 Ok
Pre-programmed Output
numbers like B001 will
display with their pre-
programmed code: e.g. S000.07. This is an output code that is programmed in Advanced Programming. Press Ok to
edit the pre-programmed output using the following simplified output characteristics
Select Output Select Group
(Program Section)
Select Condition Select Operation
B001 – B128 System Fully On, In Alarm, Siren, Fire Cadence, Was In
Alarm
Toggle, Normal, Time
Delay or Inverted
B001 – B128 Areas
Select Area #
On, Stay 2, Stay 1, Stay 1 and 2, Off, Not On, Not
Off, Alarm, Was (In) Alarm
Toggle, Normal, Time
Delay or Inverted
B001 – B128 Protection Points
Select Point #
Normal, Not Normal, Day Not Normal, Nite (Night)
Not Normal, Alarm, Bypassed, Dly prepro (Delay
Preprocess), Tamper, Point Delay, Pos (Positive)
Confirm.
Toggle, Normal, Time
Delay or Inverted
B001 – B128 Outputs
Select Output #
Real OP (output) On, Equation is True, Manual
Command
Toggle, Normal, Time
Delay or Inverted
B001 – B128 Modules
Select Module #
On Line, Tamper, Comms Trbl, (Communications
Trouble), Battry Trbl (Battery Trouble), User
Logged On,
Toggle, Normal, Time
Delay or Inverted
B001 – B128 Equipment Points
Select Point #
System Tmpr (Tamper), Low/No Battery, AC
Failure, No Phone Line, Report Delay, Time Lost,
Time Change, Progr (Program) Edit , Progr
(Program) Error, Fuse Fail, Pod (Module) Trouble,
Pod Bat (Module Battery) Low, Pod Prg (Module
Program) Edit, Pod Prg Err (Module Program
Error), Oup Troubl (Output Trouble), HSC Troubl.
Toggle, Normal, Time
Delay or Inverted
North American Output Default
Select Output Select Group
(Program Section)
Select Area,
Point, etc.
Select Condition Select
Operation
B001 Relay 1 on
motherboard
System Fire Cadence Normal
B002 Relay 2 on
motherboard
System In Alarm Normal
B003 (keypad) Areas A01: OFFICE Function Key 1 on Area 1 1
st
keypad.
Positive Trigger, 10 sec delay.
NOTE: A complex output like this must be
programmed in Advanced Programming.
Normal
B004 – B128 Undefined
Outputs (UK version)
Select Output Select Group
(Program Section)
Select Condition Select Operation
B001 – B128 System Fully On, In Alarm, Siren, Fire Cadence, Was In
Alarm, ACPO Fire, ACPO Attack, ACPO
Unconfirmed, ACPO Set, ACPO F/Faul (Fire
Fault), ACPO Bypass, ACPO Confirmed, ACPO
Siren, ACPO Strobe.
Toggle, Normal, Time
Delay or Inverted
B001 – B128 Areas
Select Area #
ACPO Fire, ACPO Attack, ACPO Unconfirmed,
ACPO Set, ACPO F/Faul (Fire Fault), ACPO
Bypass, ACPO Confirmed, ACPO Siren, ACPO
Strobe.
Toggle, Normal, Time
Delay or Inverted