21-3691Erev1.3
HSC-IP Module Installation Instructions
9 / 2008
© 2008 CSG Security Inc. / Sécurité CSG Inc. Page 3 of 13
Guardall (formerly VEREX Technology)
5201 Explorer Drive, Mississauga, Ont., Canada. L4W-4H1
sales@verextech.com +1 905.206.8434 | support@verextech.com +1 905.206.8436 | Fax: +1 905.629.4970
www.guardall.com | +1 877.249.9993
1
Telco Modem Type 1 = Bell 103, 2 = 8OP STU,
3 = WW MODEM
4 = WW MODEM 8OP
STU
Enter the selection for the
modem used.
STU = Subscriber Terminal Unit
WW = World Wide
(UK ACPO = 2)
(European = 3)
0
Telco Alarm Report
Mode
0 = not used, 1 = primary,
2 = backup, 3 = dual
4 = future
Enter “2
0
Telco Format 0 = SIA Level 2, 1 =CID
(future), 2=(future) SIA
Level 3, 3=Future
NOTE: CID communications to the HSC-IP receiver will
be available in a future version of the receiver. SIA must
be used to communicate to the HSC-IP receiver and
dialer back-up. Both forms of communication have to be
the same Telco Format.
0
Telco Sequence 0: ULC
1: UL compatible
2: Long
3: MONITOR Standard
(in Canada use 0 or 3)
Call Sequence Details: (P = Primary phone # attempt;
B = Backup phone # attempt)
0 (ULC): PPBBPPBB / delay 60 min / PPBBPPBB /
delay 60 min / PPBBPPBB / delay 60 min /
PPBBPPBB.
1 (UL): PPBBPPBBPB / delay 10 min.
2 (Long): PPPPBBBB / delay 10 min / PPPPBBBB /
delay 30 min / PPPPBBBB / delay 60 min / PPPPBBBB /
delay 2 hours / PPPPBBBB.
3 (MONITOR Standard): PPBP / delay 5 min / PPBP /
delay 10 min / PPBP / delay 30 min / PPBP / delay 60
min / PPBP / delay 2 hours / PPBP.
(no)
Telco – prioritized
reporting
9(yes) (no)
Future use.
9(yes)
Telco – never allow
blind dialing
9(yes) (no)
Dials regardless of detecting a dial tone.
(UK ACPO = 9yes)
Telco = Telephone Company
Program the dialer Primary phone number in S005È01 and the Secondary back-up phone number in S005È02.
Program the following for communications to the HSC-IP Receiver:
S005È07 Keypad Selections (left to right on keypad screen)
Default Name Selections Description
000000
HSC-IP Account # Enter the 6 digit account # that will
identify this system when it transmits
messages to the HSC-IP receiver.
This account number is also programmed
into the HSC-IP receiver.
1
HSC-IP Mode 0 = Not Used
1 = SIP1 and 2
2 = Not Used
3 = HSC POD (module)
Enter “1”
SIP = Security IP Receiver (HSC-IP)
NOTE: HSC POD (High Security Communications) is
a proprietary communications of CSG Security Inc.
and not used in all markets.
0
HSC Timeout 0 = 90sec, 1 = 3min, 2 = 5min,
3 = 10min
Leave defaulted to “0”
Delay before a line failure occurs.
0
HSC Full Report By
Area
0 = full reporting always, 1 = use area
emergency/full setting
Leave defaulted to “0”